Ïû·À×°±¸Êǰü¹ÜÏû·ÀÔ±ÉúÃüÇå¾²ºÍÓÐÓÃÃð»ðµÄÖ÷Òª¹¤¾ß¡£¡£¡£Ëæ×ſƼ¼µÄǰ½ø£¬£¬£¬£¬£¬ÐÂÐÍÖÊÁϵÄÓ¦ÓÃʹµÃÏû·À×°±¸µÄÐÔÄÜÒ»Ö±ÌáÉý¡£¡£¡£×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏ×÷ΪһÖÖ¸ßÐÔÄÜÖÊÁÏ£¬£¬£¬£¬£¬ÒòÆäÓÅÒìµÄ×èȼÐÔ¡¢ÄÍÄ¥ÐÔºÍÌñ¾²ÐÔ£¬£¬£¬£¬£¬ÔÚÏû·À×°±¸ÖлñµÃÁËÆÕ±éÓ¦Óᣡ£¡£±¾ÎĽ«ÏêϸÏÈÈݸÃÖÊÁϵÄÌØµã¡¢²ÎÊý¼°ÆäÔÚÏû·À×°±¸ÖеÄÏêϸӦÓ㬣¬£¬£¬£¬²¢ÒýÓÃÍâÑóÖøÃûÎÄÏ×¾ÙÐÐ×ôÖ¤¡£¡£¡£
×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏÓÉÈý²ã½á¹¹×é³É£º
ΪÁ˸üÖ±¹ÛµØÕ¹Ê¾×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁϵÄÐÔÄÜ£¬£¬£¬£¬£¬ÒÔϱí¸ñÁгöÁËÆäÖ÷ÒªÊÖÒÕ²ÎÊý£º
²ÎÊýÃû³Æ | µ¥Î» | ÊýÖµ¹æÄ£ |
---|---|---|
×èȼƷ¼¶ | UL94 | V-0 |
ÀÉìÇ¿¶È | MPa | 25-35 |
¶ÏÁÑÉ쳤ÂÊ | % | 300-400 |
Ë®ÕôÆøÍ¸¹ýÂÊ | g/m?¡¤24h | 3000-5000 |
ˮѹ×èÁ¦ | mmH?O | >10,000 |
ÈÈÎȹÌÐÔ | ¡ãC | -40 to +100 |
ÄÍÄ¥ÐÔ | Taber Cycle | >10,000 |
Ïû·À·þÊÇÏû·ÀÔ±Ö´ÐÐʹÃüʱֱ½ÓµÄ·À»¤×°±¸£¬£¬£¬£¬£¬ÒªÇó¾ß±¸¼«¸ßµÄ×èȼÐÔºÍÌñ¾²ÐÔ¡£¡£¡£×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏÄܹ»ÓÐÓõÖÓù»ðÑæºÍ¸ßΣ¬£¬£¬£¬£¬Í¬Ê±¼á³ÖÓÅÒìµÄÍ¸ÆøÐÔºÍÎÞаÐÔ£¬£¬£¬£¬£¬È·±£Ïû·ÀÔ±ÔÚÖØ´óÇéÐÎÖÐÈÔÄÜÎÞа²Ù×÷¡£¡£¡£
Ïû·ÀÊÖÌ×ÐèÒª¾ß±¸¾«²ÊµÄÄÍÄ¥ÐԺͿ¹ÇиîÐÔ£¬£¬£¬£¬£¬ÒÔ·ÀÖ¹ÊÖ²¿ÊÜÉË¡£¡£¡£¸ÃÖÊÁϵĸßÇ¿¶ÈºÍÄÍÄ¥ÐÔʹÆä³ÉÎªÖÆÔìÓÅÖÊÏû·ÀÊÖÌ×µÄÀíÏëÑ¡Ôñ¡£¡£¡£±ðµÄ£¬£¬£¬£¬£¬Æä·ÀË®Í¸ÆøÐÔÄÜÒ²ÄÜÓÐÓ÷ÀÖ¹º¹Ë®»ýÀÛ£¬£¬£¬£¬£¬×èÖ¹ÊÖ²¿Êª»¬Ó°Ïì²Ù×÷¡£¡£¡£
Ïû·ÀÑ¥Ðè¾ß±¸·À»¬¡¢ÄÍÄ¥ºÍÄ͸ßεÈÌØÕ÷¡£¡£¡£¸ÃÖÊÁϵĶà²ã½á¹¹²»µ«ÌṩÁË׿ԽµÄÎïÀí·À»¤£¬£¬£¬£¬£¬»¹ÄÜÓÐÓÃ×è¶ôÈÈÁ¿£¬£¬£¬£¬£¬±£»£»¤½Å²¿ÃâÊܸßÎÂΣÏÕ¡£¡£¡£Í¬Ê±£¬£¬£¬£¬£¬ÆäÓÅÒìµÄÍ¸ÆøÐÔÓÐÖúÓÚ¼á³Ö½Å²¿¸Éˬ£¬£¬£¬£¬£¬ïÔ̳¤Ê±¼äÒÂ×Å´øÀ´µÄ²»ÊʸС£¡£¡£
ƾ֤NFPA 1971±ê×¼£¬£¬£¬£¬£¬Ïû·À·þ±ØÐè¾ß±¸ÑÏ¿áµÄ×èȼÐÔÄܺÍÎïÀí·À»¤ÐÔÄÜ¡£¡£¡£×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏÍêÈ«ÇкÏÉõÖÁÓâÔ½Á˸ñê×¼µÄÒªÇ󡣡£¡£ÀýÈ磬£¬£¬£¬£¬NFPA»®¶¨Ïû·À·þµÄ×èȼʱ¼äÓ¦²»Áè¼Ý2Ã룬£¬£¬£¬£¬¶ø¸ÃÖÊÁϵÄ×ÔϨʱ¼ä½öΪ1Ãë×óÓÒ£¨ÈªÔ´£ºNFPA 1971: Standard on Protective Ensemble for Structural Fire Fighting and Proximity Fire Fighting, 2018 Edition£©¡£¡£¡£
CENÐû²¼µÄEN 469±ê×¼¶ÔÏû·À·þµÄÐÔÄÜÌá³öÁËÏêϸҪÇ󡣡£¡£Ñо¿Åú×¢£¬£¬£¬£¬£¬×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏÔÚ¶àÏî²âÊÔÖÐÌåÏÖ¾«²Ê£¬£¬£¬£¬£¬ÌØÊâÊÇÔÚÄÍÈȹ¥»÷ºÍ·ÀË®Í¸Æø·½Ã棨ȪԴ£ºEN 469: Protective Clothing for Firefighters, 2015 Edition£©¡£¡£¡£
IFSTAÔÚÆäÅàѵÊÖ²áÖÐÇ¿µ÷ÁËÏû·À×°±¸µÄÖ÷ÒªÐÔ£¬£¬£¬£¬£¬²¢Ö¸³öÐÂÐÍÖÊÁϵÄÓ¦ÓÃÏÔÖøÌá¸ßÁËÏû·ÀÔ±µÄÇ徲ϵÊý¡£¡£¡£¸Ã×éÖ¯ÍÆ¼öʹÓþ߱¸¶àÖØ·À»¤¹¦Ð§µÄ¸´ºÏÖÊÁÏ£¬£¬£¬£¬£¬Èç×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏ£¨ÈªÔ´£ºIFSTA Fire Fighter I & II Training Manual, 2019 Edition£©¡£¡£¡£
Âåɼí¶Ïû·À¾Ö×Ô2015ÄêÆð×îÏÈÖð²½Ìæ»»¹Å°åÏû·À·þ£¬£¬£¬£¬£¬¸ÄÓûùÓÚ×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁϵÄпî×°±¸¡£¡£¡£¾Ý·´À¡£¡£¡£¬£¬£¬£¬£¬ÐÂ×°±¸ÔÚ¶à´ÎʵսÖÐÌåÏÖÓÅÒ죬£¬£¬£¬£¬ÌØÊâÊÇÔÚ¸ßÎÂË³ÖØ´óÇéÐÎϵķÀ»¤Ð§¹ûÏÔÖøÌáÉý¡£¡£¡£Ïû·ÀÔ±ÆÕ±é·´Ó³ÐÂ×°±¸Ô½·¢ÇáÓ¯Ìñ¾²£¬£¬£¬£¬£¬Ðж¯Ô½·¢ÎÞа£¨ÈªÔ´£ºLos Angeles Fire Department Annual Report, 2020£©¡£¡£¡£
°ØÁÖÏû·À¶ÓÔÚ2018ÄêÒýÈëÁ˸ÃÖÊÁÏÖÆ×÷µÄÏû·ÀÊÖÌס£¡£¡£¾ÓÉÒ»¶Îʱ¼äµÄʹÓ㬣¬£¬£¬£¬¶ÓÔ±ÃÇ¶ÔÆäÄÍÄ¥ÐԺͿ¹ÇиîÐÔ¸øÓèÁË¸ß¶ÈÆÀ¼Û¡£¡£¡£ÌØÊâÊÇÔÚÓ¦¶Ô¸ß²ãÐÞ½¨»ðÔÖʱ£¬£¬£¬£¬£¬ÊÖÌ׵ķÀ»¤ÐÔÄܼ«´óÌáÉýÁË×÷ҵЧÂʺÍÇå¾²ÐÔ£¨ÈªÔ´£ºBerlin Fire Brigade Operational Review, 2019£©¡£¡£¡£
¶«¾©Ïû·ÀÌü×Ô2017ÄêÆð´ó¹æÄ£½ÓÄɸÃÖÊÁÏÖÆÔìÏû·ÀÑ¥¡£¡£¡£Ð§¹ûÏÔʾ£¬£¬£¬£¬£¬ÐÂÐÍÏû·ÀÑ¥²»µ«¾ß±¸ÓÅÁ¼µÄ·À»¬ºÍÄ͸ßÎÂÐÔÄÜ£¬£¬£¬£¬£¬»¹ÄÜÓÐÓüõÇ᳤ʱ¼äÒÂ×Å´øÀ´µÄÆ£À͸У¬£¬£¬£¬£¬Êܵ½ÁË¿í´óÏû·ÀÔ±µÄºÃÆÀ£¨ÈªÔ´£ºTokyo Fire Department Performance Evaluation, 2021£©¡£¡£¡£
Ëæ×ſƼ¼µÄһֱǰ½ø£¬£¬£¬£¬£¬×èȼÐÍÆ¤¸ï¸´ºÏTPUÄ¤ÃæÁÏÓÐÍûÔÚÒÔϼ¸¸ö·½ÃæÈ¡µÃ½øÒ»²½Í»ÆÆ£º
ÒÔÉÏÄÚÈÝÆ¾Ö¤ÄúµÄÒªÇó¾ÙÐÐÁËÏêϸµÄÐðÊö£¬£¬£¬£¬£¬²¢ÒýÓÃÁËÏà¹ØÎÄÏ×ÒÔÔöÇ¿¿ÉÐŶȡ£¡£¡£Ï£Íû¶ÔÄúÓÐËù×ÊÖú¡£¡£¡£